How to Boot Linux from Intel® Optane™ Persistent Memory

Posted on December 26, 2019  •  10 minutes

Introduction

In this article, I will demonstrate how to configure a system with Intel Optane Persistent Memory (PMem) and use part of the PMem as a boot device. This little known feature can reduce boot times for those that need it.

The basic steps include:

Configure the Persistent Memory

The following figure shows how we will provision the persistent memory.

A namespace can be provisioned to operate in one of 4 modes, fsdax, devdax, sector, and raw. For a boot device, we want to use sector since one of its use cases is for boot devices:

sector: Use this mode to host legacy filesystems that do not checksum metadata or applications that are not prepared for torn sectors after a crash. The expected usage for this mode is for small boot volumes. This mode is compatible with other operating systems.

Reference: ndctl-create-namespace(1) man page

There are many ways to configure persistent memory using the BIOS menus, Platform Manager (BMC, iLO, iDRAC, etc), or the ipmctl utility in either the UEFI Shell or Operating system if you have one currently installed. If you do not currently have an operating system installed, refer to your server documentation and follow the steps to configure Persistent Memory.

For this article, we will assume the persistent memory has no existing configuration and data. The system I will be using is an Intel S2600WFD whitebox (codename: Wolfpass) with 2 x Intel Xeon Platinum 8260L CPUs, 12 x 16GiB DDR DIMMs (384GiB total), and 12 x 256GiB Persistent Memory Modules (3TiB total). The system has 4 x Intel P545 (475GiB) and 4 x Intel P4610 (3.2TiB) internal drives.

We can use ipmctl show -dimm to see the persistent memory modules:

$ sudo ipmctl show -dimm

 DimmID | Capacity  | HealthState | ActionRequired | LockState | FWVersion
==============================================================================
 0x0001 | 252.5 GiB | Healthy     | 0              | Disabled  | 01.02.00.5417
 0x0011 | 252.5 GiB | Healthy     | 0              | Disabled  | 01.02.00.5417
 0x0021 | 252.5 GiB | Healthy     | 0              | Disabled  | 01.02.00.5417
 0x0101 | 252.5 GiB | Healthy     | 0              | Disabled  | 01.02.00.5417
 0x0111 | 252.5 GiB | Healthy     | 0              | Disabled  | 01.02.00.5417
 0x0121 | 252.5 GiB | Healthy     | 0              | Disabled  | 01.02.00.5417
 0x1001 | 252.5 GiB | Healthy     | 0              | Disabled  | 01.02.00.5417
 0x1011 | 252.5 GiB | Healthy     | 0              | Disabled  | 01.02.00.5417
 0x1021 | 252.5 GiB | Healthy     | 0              | Disabled  | 01.02.00.5417
 0x1101 | 252.5 GiB | Healthy     | 0              | Disabled  | 01.02.00.5417
 0x1111 | 252.5 GiB | Healthy     | 0              | Disabled  | 01.02.00.5417
 0x1121 | 252.5 GiB | Healthy     | 0              | Disabled  | 01.02.00.5417

We will start by creating an AppDirect goal (aka configuration) using the ipmctl utility. This creates two 1.5TiB regions, one per CPU socket and interleaves all the modules on the socket.

$ sudo ipmctl create -goal PersistentMemoryType=AppDirect

The following configuration will be applied:
 SocketID | DimmID | MemorySize | AppDirect1Size | AppDirect2Size
==================================================================
 0x0000   | 0x0001 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0000   | 0x0011 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0000   | 0x0021 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0000   | 0x0101 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0000   | 0x0111 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0000   | 0x0121 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0001   | 0x1001 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0001   | 0x1011 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0001   | 0x1021 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0001   | 0x1101 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0001   | 0x1111 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0001   | 0x1121 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
Do you want to continue? [y/n] y
Created following region configuration goal
 SocketID | DimmID | MemorySize | AppDirect1Size | AppDirect2Size
==================================================================
 0x0000   | 0x0001 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0000   | 0x0011 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0000   | 0x0021 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0000   | 0x0101 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0000   | 0x0111 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0000   | 0x0121 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0001   | 0x1001 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0001   | 0x1011 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0001   | 0x1021 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0001   | 0x1101 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0001   | 0x1111 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
 0x0001   | 0x1121 | 0.0 GiB    | 252.0 GiB      | 0.0 GiB
A reboot is required to process new memory allocation goals.

The system needs to be rebooted for the change to take effect.

$ sudo systemctl reboot

When the system comes back up, we should see two regions, one per CPU socket.

$ sudo ipmctl show -region

 SocketID | ISetID             | PersistentMemoryType | Capacity   | FreeCapacity | HealthState
================================================================================================
 0x0000   | 0x2d3c7f48f4e22ccc | AppDirect            | 1512.0 GiB | 1512.0 GiB   | Healthy
 0x0001   | 0xdd387f488ce42ccc | AppDirect            | 1512.0 GiB | 1512.0 GiB   | Healthy

Create a sector namespace using an installed operating system

If you have an operating system already installed on an internal drive, or an image is available over the network with the ndctl utility already installed, we will use this to create a new sector namespace. We don’t need the entire PMem (1.5TiB) for the operating system, so we’ll create a smaller 60GiB namespace for the operating system on each Region.

$ sudo ndctl create-namespace --mode sector --size 60g --region 0
{
  "dev":"namespace0.0",
  "mode":"sector",
  "size":"59.94 GiB (64.36 GB)",
  "uuid":"764224fb-e8b0-41a3-ac3f-0b02832ce17f",
  "sector_size":4096,
  "blockdev":"pmem0s"
}

$ sudo ndctl create-namespace --mode sector --size 60g --region 1
{
  "dev":"namespace1.0",
  "mode":"sector",
  "size":"59.94 GiB (64.36 GB)",
  "uuid":"38b709a4-0caf-481c-bdad-0f353b2629f3",
  "sector_size":4096,
  "blockdev":"pmem1s"
}

The “blockdev" field tells us a /dev/pmem0s and /dev/pmem1s device was created. We can see these new devices using lsblk:

$ lsblk /dev/pmem0s /dev/pmem1s
NAME   MAJ:MIN RM  SIZE RO TYPE MOUNTPOINT
pmem0s 259:2    0 59.9G  0 disk
pmem1s 259:3    0 59.9G  0 disk

Create a sector namespace using the BIOS or Platform Manager

You need to follow the documented procedure for configuring App Direct and Namespaces for your specific server vendor and server model. Here are some links to common server OEM documentation to help you:

Create a bootable Fedora USB drive

For this article, we’ll install Fedora Server 34, but most Linux distros that support Intel Optane Persistent Memory will work. If you have a network installation service, you can skip this section.

Grab the ISO from https://getfedora.org/en/server/download/

$ wget https://download.fedoraproject.org/pub/fedora/linux/releases/34/Server/x86_64/iso/Fedora-Server-dvd-x86_64-34-1.2.iso

Use the wipefs command to erase any existing partitions and file systems on the USB device (/dev/sde).

$ sudo wipefs -a /dev/sde
/dev/sde: 5 bytes were erased at offset 0x00008001 (iso9660): 43 44 30 30 31
/dev/sde: 2 bytes were erased at offset 0x000001fe (dos): 55 aa
/dev/sde: 8 bytes were erased at offset 0x00000200 (gpt): 45 46 49 20 50 41 52 54
/dev/sde: calling ioctl to re-read partition table: Success

Use the dd utility to write the ISO contents to the USB device.

$ sudo dd if=Fedora-Server-dvd-x86_64-34-1.2.iso of=/dev/sde bs=8M status=progress oflag=direct

Install Fedora Server 34

Reboot the system and press F6 to enter the Boot Manager. Select the USB device for the installation media.

After a few seconds, a menu appears. Select ‘Install Fedora 34’:

Select your language from the options and click ‘Continue’:

Click on ‘Installation Destination’

Click ‘Add a disk…’ under ‘Specialized & Network Disks’

The pmem0s and pmem1s devices we created earlier should be listed in the default list

If you have a lot of disks, the pmem0s and pmem1s devices will also appear under the ‘NVDIMM Devices’ tab

Select the pmem0s device and click ‘Done’ to install Fedora to a single device, or select both pmem0s and pmem1s if you intend to use Logical Volume Manager to mirror the boot devices. Click ‘Done’.

The pmem0s device will now be listed and checked as the installation device. You can choose whether to let the installer automatically partition the device (default), or select ‘Custom’ to manually define the partitions and their size.

Once the device has been partitioned, click ‘Done’ to return to the main installer screen where you can configure the timezone, packages to install, root password, non-root user and password, etc, then proceed with the installation.

Once the installation completes, reboot the system, Press F6 to enter the Boot Manager and select ‘Fedora’ or the ‘UEFI Misc Device’ from the Boot Manager list. You can use the BIOS to change the boot order.

Once the system boots, you can confirm the OS booted from the PMem device:

# df -h
Filesystem                      Size  Used Avail Use% Mounted on
devtmpfs                        189G     0  189G   0% /dev
tmpfs                           189G     0  189G   0% /dev/shm
tmpfs                            76G  2.8M   76G   1% /run
/dev/mapper/fedora_fedora-root   15G  1.3G   14G   9% /
tmpfs                           189G  4.0K  189G   1% /tmp
/dev/pmem0s2                   1014M  177M  838M  18% /boot
/dev/pmem0s1                    599M  6.1M  593M   2% /boot/efi
tmpfs                            38G     0   38G   0% /run/user/0

What about the other Linux Distros?

I need to experiment with other popular Linux Distros such as CentOS/RHEL 7.x and 8.x, Ubuntu, SUSE, etc to see if they behave in the same way. I performed some early experiments on Ubuntu 19.04 and found the OS couldn’t boot as it was missing PMem drivers in the initramfs, but this may have been resolved in later versions.

How Fast is the Boot?

To check how fast the boot is, we use the systemd-analyze utility that is installed on all systemd Linux Distro’s. To confirm:

# which systemd-analyze
/usr/bin/systemd-analyze

To find out the actual boot time of the machine, use the systemd-analyze command with no arguments:

$ sudo systemd-analyze
Startup finished in 5.735s (kernel) + 13.825s (initrd) + 13.562s (userspace) = 33.123s
multi-user.target reached after 13.541s in userspace

To better understand where the time is spent, use the systemd-analyze blame command:

$ sudo systemd-analyze blame
6.177s NetworkManager-wait-online.service
6.112s systemd-udev-settle.service
1.033s lvm2-monitor.service
 430ms initrd-switch-root.service
 357ms [email protected]
 334ms systemd-hwdb-update.service
 326ms lvm2-pvscan@8:19.service
 323ms lvm2-pvscan@8:3.service
 312ms lvm2-pvscan@8:35.service
 306ms dracut-initqueue.service
 249ms firewalld.service
 220ms initrd-parse-etc.service
 216ms [email protected]
 148ms sysroot.mount
 148ms systemd-udev-trigger.service
 142ms dracut-cmdline.service
 126ms lvm2-pvscan@259:6.service
 110ms sssd.service
 109ms systemd-resolved.service
  96ms abrtd.service
  73ms systemd-vconsole-setup.service
  70ms dracut-pre-pivot.service
  [...snip...]

You can also have the systemd-analyze command print the results in a chain (tree) of events style with the command:

$ sudo systemd-analyze critical-chain
The time when unit became active or started is printed after the "@" character.
The time the unit took to start is printed after the "+" character.

multi-user.target @13.541s
└─getty.target @13.541s
  └─[email protected] @13.540s
    └─plymouth-quit-wait.service @13.507s +28ms
      └─systemd-user-sessions.service @13.475s +21ms
        └─remote-fs.target @13.467s
          └─remote-fs-pre.target @13.466s
            └─nfs-client.target @7.302s
              └─gssproxy.service @7.286s +14ms
                └─network.target @7.279s
                  └─NetworkManager.service @7.252s +26ms
                    └─network-pre.target @7.249s
                      └─firewalld.service @6.999s +249ms
                        └─polkit.service @7.902s +51ms
                          └─basic.target @6.990s
                            └─dbus-broker.service @6.953s +33ms
                              └─dbus.socket @6.943s
                                └─sysinit.target @6.928s
                                  └─systemd-update-utmp.service @6.913s +14ms
                                    └─auditd.service @6.840s +69ms
                                      └─systemd-tmpfiles-setup.service @6.780s +53ms
                                        └─import-state.service @6.720s +56ms
                                          └─local-fs.target @6.713s
                                            └─boot-efi.mount @6.685s +27ms
                                              └─systemd-fsck@dev-disk-by\x2duuid-3557\x2dFDD8.service @6.643s +38ms
                                                └─local-fs-pre.target @6.635s
                                                  └─lvm2-monitor.service @358ms +1.033s
                                                    └─dm-event.socket @341ms
                                                      └─-.mount
                                                        └─-.slice

You can produce a Scalable Vector diagram of the entire boot process using:

$ sudo systemd-analyze plot > pmem0_boot.svg

Here’s the output from my system:

And that’s how you can use the systemd-analyze tool to help you observe boot times and behavior. To learn more about the systemd-analyze tool, issue the command man systemd-analyze and read all about it.

Related Posts

How to Boot Linux from Intel® Optane™ Persistent Memory

Introduction In this article, I will demonstrate how to configure a system with Intel Optane Persistent Memory (PMem) and use part of the PMem as a boot device. This little known feature can reduce boot times for those that need it. The basic steps include: Configure the Persistent Memory in AppDirect Interleaved Create two small SECTOR namespaces, one per Region Install the OS and select one or both of the namespaces (single disk install, or mirrored LVM)

Read More

How To Enable Debug Logging in ipmctl

The ipmctl utility is used for configuring and managing Intel Optane Persistent Memory modules (DCPMM/PMem). It supports the functionality to: Discover Persistent Memory on the server Provision the persistent memory configuration View and update the firmware on the persistent memory modules Configure data-at-rest security Track health and performance of the persistent memory modules Debug and troubleshoot persistent memory modules I wrote the IPMCTL User Guide showing how to use the tool, but what if ipmctl returns an error or something you’re not expecting?

Read More

How To Emulate CXL Devices using KVM and QEMU

What is CXL? Compute Express Link (CXL) is an open standard for high-speed central processing unit-to-device and CPU-to-memory connections, designed for high-performance data center computers. CXL is built on the PCI Express physical and electrical interface with protocols in three areas: input/output, memory, and cache coherence. CXL is designed to be an industry open standard interface for high-speed communications, as accelerators are increasingly used to complement CPUs in support of emerging applications such as Artificial Intelligence and Machine Learning.

Read More